FORCE Technology has a large range of test facilities and can conduct test according to the majority of product standards and generic standards.

Emission

Type: Semi-anechoic (walls and ceilings covered with absorbers, and the floor is reflective)
Semi-anechoic chambers (SAC).
The floor can be covered with absorbers, Full-anechoic room (FAR).
Frequency range (radiated and conducted emission): 9 kHz – 40 GHz
Dimensions (LxWxH): 20.1x13.0x8.8 m
Port dimension (WxH): 3x3 m
Door dimension (WxH): 1.2x2.1 m
Measuring distances (emissions): 1 m, 3 m and 10 m
Load capacity (floor): max. 10.000 kg/m2

Rotating Platform

Dimensions (diameter): 5 m
Load: max. 10.000 kg (distributed)

Hydraulic lift platform at the entrance to the SAC

Load: max. 10.000 kg (distributed)

Immunity

HF radiation

Frequency range: 26 MHz – 40 GHz
Field strength: max. 1000 V/m (depending on the frequency range and the test method)

ESD test

Test level: ± 30 KV

Fast transient/burst

Test level: ± 4.8 KV

Surge

Test level: ± 10 KV

Conducted immunity

Frequency range: 9 kHz – 230 MHz.
Level: max. 30 V/rms or 260 mA

Magnetic field

50/60 Hz, 1000 A/m

General conditions

Power supply options

230 VAC / 50 Hz (phase+0), 400 VAC / 50 Hz (3 phases+0) max 125 A

Signal connections

Ethernet, VGA, DVI, D-sub, USB, HDMI, CAN, RS232, VDC, VAC etc.

Other

Air, water.