Ensure robustness of electronic products with EMC self-pre-testing
Test the robustness of your electronic products against electromagnetic interference using our advanced facilities. EMC Club membership provides access to expert advice and state-of-the-art equipment.
EMC pre-testing gives a preliminary idea of how your product will perform in various real-world scenarios
We offer comprehensive EMC pre-testing services to ensure your electronic products can withstand electromagnetic interference. This testing gives an early idea of how your product will perform in various real-world scenarios, such as near mobile phones, routers and RF transmitters.
Using our advanced facilities during the product development phase, you can identify and address potential issues early, ensuring your products meet EMC requirements and pass type approval tests with minimal problems.
EMC Club membership gives you access to do-it-yourself testing facilities
Becoming a member of the EMC Club grants automatic access to our do-it-yourself testing facilities. Members can test their products against basic EMC standards and receive hands-on training in these standards during three of the club's ten annual meetings. Members can also access our EMC specialists for advice and assistance during testing.
Our membership programme provides access to state-of-the-art testing equipment, methodical testing instructions, and the opportunity to purchase expert consultancy, ensuring a successful and thorough pre-testing process.
Join the EMC club
Get access to the latest knowledge about EMC requirements, design, testing, and approval, and meet your peers.Facility specifications
Specifications
Frequency range (radiated and conducted emission): 9 kHz - 2 GHz
Emission/Immunity
ESD test
- Test level: ± 15 KV
Fast transient/burst
- Test level: ± 4 KV
Surge
- Test level: ± 4 KV
Conducted immunity
- Frequency range: 0.15 - 80 MHz.
- Field strength: max. 10 V/rms
Magnetic field
- 50/60 Hz, 30A/m
- Dimensions (LxWxH): 5.1 x 4.1 x 3.1 m
- Door dimension (WxH): 1.1 x 2.15 m
- Type: Shielded enclosure without absorbers
- Power supply conditions: 230 VAC 50 Hz (phase + 0) and 400 VAC (3 phase + 0). Max. 16 A per phase
- Signal connections: Ethernet, VGA, DVI, D-sub, USB, HDMI, VDC, etc.
- Compressed air
HF radiation
- Frequency range: 26 MHz - 6 GHz
- Field strength: max. 20 V/rms
- Type: Anechoic shielded enclosure
- Dimensions (LxWxH) less than: 7.5 x 4.1 x 3.19 m
- Door dimension (WxH): 1.2 x 2.05 m
- Power supply conditions: 230 VAC / 50 Hz (phase+0),
- 400 VAC / 50 Hz (3 phase+0) max. 32 amp.
- Signal connections: Ethernet, VGA, DVI, D-sub, USB,
- HDMI, VDC, etc.
- Air
- Water
![Product compliance kundecenteret testcenter lab](/-/media/force-technology-media/images/contacts/m-n-o-p/product-compliance-kundecenter-test-lab.png?ca=Slideshow-XS&r=c6f9022d-b30c-4eca-a16e-93000016245e)
For more information, contact
Compliance & Product Testing
Customer Centre: Consultancy, test and product approval
T: +45 43 25 14 50